MULTI-POINT DISTRIBUTION
Feed many silos and machines automatically with a single conveying line
Multi-point distribution is a system in which several destinations are fed by the same pneumatic line. Each destination's level sensor reports to the PLC; when a destination runs low, the relevant valve switches position and conveying is directed to it. There is no need to build a separate line and conveying unit for every destination.
At OPTA Mühendislik we build distribution systems with diverter valves connected in series or single-body multi-outlet distributors. Priority order, prevention of cross-contamination and line purging are defined in the automation.

Distribution methods
| Diverter valves in series | Multi-outlet distributor | |
|---|---|---|
| Construction | Two-way valves one after another along the line | Rotary distributor in a single body |
| Number of destinations | Flexible, can be added later | Fixed by the body (4 – 12) |
| Layout | Destinations spread along the line | Destinations branch from the same point |
| Pressure drop | Increases with the number of valves | Low, single pass |

Distribution by automation
Each destination's minimum and maximum level sensors are connected to the PLC. The PLC queues the destinations running low by priority, positions the valves and starts conveying.
- Valve position feedback
- Interlock against conveying to the wrong destination
- Line purge cycle
- Monitoring from SCADA
Equipment and standards
Standard
- Diverter valves
- Position sensors
- Level sensors
- PLC distribution software
Optional
- Multi-outlet distributor
- Wear-resistant valve body
- SCADA screen
- Line purge valves
Standards
- ATEX 2014/34/EU
- Machinery Directive 2006/42/EC
More in Distribution
Diverter valvesValves that divert one line to several destinations.→All distributionPneumatic Conveying→Frequently asked questions
How many destinations can be connected to one line?
It depends on pressure drop and cycle time; in practice 10–12 destinations is common.
Can different materials be distributed through the same line?
Yes, but a line purge cycle and a material changeover procedure are defined to avoid cross-contamination.
Can a new destination be added to an existing line?
With series valve systems usually yes; a new valve and level sensor are added and the software is updated.
Let’s work together on multi-point distribution
Tell us about your raw material, capacity and site, and we will come back with a preliminary design and quotation.