HEATED AND COOLED TANKS
Keep liquid raw materials at the right temperature with jacketed and coil-heated tanks
Some liquid raw materials can only be pumped, dosed or used within a certain temperature range. Resins, waxes, oils and viscous chemicals solidify in the cold, while some products degrade at high temperatures. Heated and cooled tanks keep the product at the required temperature and keep the process running.
At OPTA Mühendislik we build double-wall (jacketed), half-pipe jacketed and internal-coil tanks. For heating we use hot water, steam, thermal oil or electric heaters; for cooling, cooling water or a glycol circuit, with temperature control automated by PLC.

Heating and cooling methods
| Double wall (jacket) | Half-pipe jacket | Internal coil | |
|---|---|---|---|
| Heat transfer surface | Large, uniform | Large, high pressure resistant | Limited, inside the product |
| Suitable medium | Hot water, cooling water | Steam, thermal oil | Hot water, steam |
| Cleaning | Easy, smooth inner surface | Easy, smooth inner surface | Difficult around the coil |
| Typical use | Temperature holding | Fast heating, high temperature | Large storage tanks |

How is temperature controlled?
Tank temperature is measured with a PT100 sensor; the PLC maintains the set point by controlling the proportional valve in the heating or cooling circuit, or the heater. If needed, an agitator ensures uniform temperature inside the tank.
- Product temperature is measured by PT100
- The PLC compares it with the set point
- The proportional valve / heater is activated
- Alarms and records are sent to SCADA
Equipment and standards
Standard
- Jacketed stainless shell
- PT100 temperature sensor
- Rock wool insulation and stainless cladding
- Jacket safety valve
Optional
- Agitator
- Thermal oil unit / boiler connection
- Glycol cooling
- Heat-traced piping
Standards
- PED 2014/68/EU (jacket pressure)
- ATEX (for flammable products)
- Calculation based on EN 13445
More in Liquid tanks
Liquid storage tanksVertical and horizontal stainless storage tanks.→All liquid tanksRaw Material Storage→Frequently asked questions
Which heating method should I choose?
It depends on your available energy source and the temperature the product requires. Below 90 °C hot water is preferred; above that, steam or thermal oil.
What if the product solidifies in the pipeline?
For heated products we design pipelines with jacketed pipe or electric heat tracing together with insulation.
Can you add a jacket to my existing tank?
Depending on the shell condition, a half-pipe jacket or heating panels can be added externally; we make a recommendation after inspecting on site.
Let’s work together on heated and cooled tanks
Tell us about your raw material, capacity and site, and we will come back with a preliminary design and quotation.